From shibata@hotaka.mtk.nao.ac.jp Mon Feb 07 01:46:59 2000
Return-Path: <shibata@hotaka.mtk.nao.ac.jp>
Delivered-To: pge@vsop.isas.ac.jp
Received: (qmail 12209 invoked by uid 1097); 7 Feb 2000 01:46:58 -0000
Delivered-To: vsog@vsop.isas.ac.jp
Received: (qmail 12204 invoked from network); 7 Feb 2000 01:46:57 -0000
Received: from hotaka.mtk.nao.ac.jp (133.40.105.6)
  by perseus.vsop.isas.ac.jp with SMTP; 7 Feb 2000 01:46:57 -0000
Received: from [133.40.121.239] ([133.40.121.239])
	by hotaka.mtk.nao.ac.jp (8.9.3/3.7Wpl2/08/11/99) with SMTP id KAA12424;
	Mon, 7 Feb 2000 10:38:09 +0900 (JST)
Message-Id: <200002070138.KAA12424@hotaka.mtk.nao.ac.jp>
Date: Mon, 7 Feb 2000 10:43:33 +0900
To: vsog@vsop.isas.ac.jp
From: shibata@hotaka.mtk.nao.ac.jp (SHIBATA, Katsunori, M.)
Subject: VSOP : vs05f
Cc: nakagawa@hotaka.mtk.nao.ac.jp
MIME-Version: 1.0
Content-Type: text/plain; charset=iso-2022-jp
X-Mailer: Eudora-J(1.3.8.8r7-J16)
Status: RO

Dear PI, 

I will sending herewith a PI letter for vs05f. 
FITS file will be sent to you with 4 mm MT. 

Best regards, 

K. M. Shibata
Mitaka correlator

===========================================
MITAKA Correlation Summary  2000/02/05

Obscode:vs05f
Obsdate:1999/08/20

PI:       The VSOP Survey Program

  Address:  Institute of Space and Astronautical Science, Hirabayashi Lab.
            3-1-1 Yoshinodai, Sagamihara, Kanagawa 229
            JAPAN

VS05f was treated as v99232 during correlation. 
We made the following Data quick look. 

1. Baselines vs. time plots and u-v plots were made for each correlation path. 

2. Delay residuals and rate residuals plots were made for all stations.
These were the results of fringe finding, so the station in which fringes
were not found showed large scattering. 

3. Amplitude and phase plots were made for baselines in which fringes were
detected. 

4. Autocorrelation bandpass plots were generated for all antennas for scan
on 'J0336+32'. 

5. Cross-correlation bandpass plots were made for baselines in which
fringes were detected for scan on 'J0336+32'. 

NOTES: 

NT - Not observed. 

TR - Not observed. 

UZ - No fringe was detected.

TZ - Fringes were detected in the whole time.

NOTES for REDUCTION:
The unit of output amplitude is arbitrary. Use ACCOR just after loading to
the AIPS. 

Set DIGICOR = -1 and DELCORR = -1 in FITLD. 

Delete NX and CL tables just after FITLD, then re-build by INDXR. 

DO NOT use PHNEG!!  These FITS data are no longer necessary to use PHNEG. 

IF YOU HAVE ANY QUESTION AND PROBLEM ABOUT FITS DATA, please contact with 
mtkfx@hotaka.mtk.nao.ac.jp. 