Errors in Processing for Sequence 203046010, version 1

This page gives a list of all the errors encountered in processing this sequence.

The following information is also available:


  1. E2: Error from HEAdas Task ahscreen - exit status 137
  2. E2: WARNING: ahscreen error detected for xa203046010xtd_s0320000a0_uf.evt,xa203046010xtd_p0320000a0_uf.evt. Results from this step will be suspect! (Status=137)
  3. E2: Error from FTOOL ftkeypar - exit status 45
  4. E2: Error from HEAdas Task ahscreen - exit status 137
  5. E2: WARNING: ahscreen error detected for xa203046010xtd_s0320000a0_uf.evt,xa203046010xtd_p0320000a0_uf.evt. Results from this step will be suspect! (Status=137)
  6. E2: Error from FTOOL ftkeypar - exit status 45
  7. E2: Error from HEAdas Task ahscreen - exit status 3
  8. E2: ahscreen: Filtered all events during event screening for output file xa203046010rsl_a0px0000_nxb.evt.
  9. E2: Error from HEAdas Task ahscreen - exit status 3
  10. E2: ahscreen: Filtered all events during event screening for output file xa203046010rsl_a0px1000_nxb.evt.
  11. E1: There are no valid GTI from EHK label PIXELNTE.
  12. E1: Cannot screen Resolve NTE.
  13. E1: There are no valid GTI from EHK label PIXELNTE.
  14. E1: Cannot screen Resolve NTE.
  15. E1: There are no valid GTI from EHK label PIXELNTE.
  16. E1: Cannot screen Resolve NTE.
  17. E1: There are no valid GTI from EHK label PIXELNTE.
  18. E1: Cannot screen Resolve NTE.
  19. E1: Leftover file: busy.stream.control
  20. E1: Leftover file: stream.pid